Design
Select your part geometry and define your weld, probe, wedge, and groups
for your inspection directly on your computer for fast setup preparation.
Export and Import
Once you have completed the definition of the inspection configuration in
NDT SetupBuilder, you can export the parameters with just one click and
import them into the OmniScan MX2 and SX flaw detectors.
Inspect
Once the configuration is imported to the OmniScan MX2 and SX flaw
detectors, adjust your parameters, and then calibrate. The OmniScan MX2 and
SX flaw detectors are now fully functional.
Analyze and Report
Inspection data is transferred from the OmniScan to the OmniPC software on
your computer for analysis and reporting. That leaves the OmniScan
available to scan another part.
OmniPC is a PC-based data analysis and reporting
software that benefits from the same user
interface, analysis and reporting features as the
OmniScan.
Analysis
With OmniPC, the OmniScan unit can now be used
strictly for scanning while analysis is performed
simultaneously on a personal computer. This
software can also be used in conjunction with
extra-large screens for increased visibility, and
with keyboard shortcuts for faster operations.
OmniPC software benefits from the same user
interface as the OmniScan software. No need to
learn new software for the analysis of your
OmniScan data files.
Export C-Scan
OmniPC adds a new feature for corrosion
applications. You can export the complete C-Scan
values to a *.txt file for further analysis. The
values can be visualized in the Notepad, Excel,
Matlab or any other software in which you wish to
do your analysis.
Perform your acquisition on any
OmniScan instrument.
Export as a .txt file and perform
analysis on the software of your
choice.
OmniPC Features
インターフェース
- Same Interface as the OmniScan
Software - Full screen mode
- Available A-scan visual references
(sizing curve, TCG, ref amplitude,
grid) - Volumetric linked view
- Predefined weld-overlay display
- End View with merged signal
- Multigroup combined display
- Ability to zoom in/out
Ease of Use
- Available online help
- Intuitive contextual menus
- Keyboard and mouse shortcuts to
boost the productivity level - Predefined lists of readings based
on common applications - 8 selectable readings
simultaneously displayed
Analysis
- Lateral-wave (LW) synchronization
- TOFD calibrations
- Gate adjustment and synchronization
(by group/context) - Export C-Scans to .txt files
- Ability to display and edit
indication tables - Built-in report generator
(customizable) - Ability to include an image of each
indication in the report - Software attenuation gain